- Property:Three-bedroom semi-detached house
- Location:Meltham, Huddersfield
- Client:Prospective purchaser
- Services:RICS Home Survey Level 2
We were instructed to carry out a RICS Home Survey Level 2 on a three-bedroom semi-detached property in Meltham, Huddersfield. The property was of traditional construction, dating from around 1970, with a later single-storey rear extension.

Properties of this age often combine original construction with later alterations and improvements added over time. Here, retrospectively installed cavity wall insulation was a key factor to consider.
Such improvements are meant to boost thermal performance, but our inspection identified internal dampness and moisture patterns that raised questions about how the insulation had been installed and how well it was performing.
Floor coverings, furniture and stored possessions restricted our access to some areas. A Level 2 survey needed to do more than record visible defects: we needed to read the patterns behind them and point to where further investigation was needed.
Significant damp and moisture ingress
We identified dampness internally, particularly to the gable and rear walls. The pattern was consistent with problems that can occur when retrospective cavity wall insulation becomes damp and bridges the cavity, allowing moisture to reach the internal wall surfaces.
Roof & rainwater defects contributing to damp
We also flagged maintenance concerns with the roof and rainwater disposal system. Moss and lichen on the rear roof slope appeared to be restricting rainwater discharge, and we suspected the guttering was partially or fully blocked. Staining above the rear bedroom windows was consistent with prolonged water ingress, potentially involving gutter overflow together with wind-driven rain.
These findings mattered because they showed the moisture problems couldn’t simply be dismissed as an isolated cosmetic issue.
Drainage requiring urgent investigation
Inspecting a manhole in the front garden, we found a blockage and defects in the drainage system. We also noted movement to the surrounding paving, potentially linked to a leaking drain. We recommended a CCTV drainage survey to establish the extent of the problem before our client became legally committed.
Garage condition
Although access to the detached garage was restricted, its visible condition raised clear concerns. A severely decayed timber window frame presented a risk of falling glazing, while plastic sheeting over the roof suggested active water ingress. We recommended further internal investigation and included its unknown condition in our summary of risks.
Potential asbestos-containing materials
Given the property’s age, we also flagged the potential for asbestos-containing materials. The flue was a particular area of concern. Rather than assume asbestos was present, we gave proportionate advice: a specialist asbestos survey should be commissioned before any refurbishment, alteration or demolition work that could disturb these materials.




Together, these findings gave our client a clear, evidence-based picture of the property’s condition ahead of exchange, highlighting risks a routine viewing would have missed and giving them the grounds to negotiate or investigate further with confidence.